Sound transmission through wood joist floor/ceiling systems: A study of the effects of sound absorbing materials and changes to the ceiling structure (A)

A. C. C. Warnock and M. J. Morin

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S134-S134 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
A wood joist floor system was constructed in the Acoustics Laboratory at NRC. Measurements of airborne and impact sound transmission were made for different types and amounts of sound absorbing material in the cavity. Differences between materials were small. Different makes of resilient metal channels were installed; all gave about the same results. Methods of improving an unsatisfactory floor were examined. Over 20 floor systems were measured. The study was funded by Canada Mortgage and Housing Corporation. Measurements were made down to 63 Hz and revealed that in many cases there are resonances occurring below 125 Hz that have a strong influence on transmission loss values at and above 125 Hz. While the causes of the resonances are not always clear, measurements to these low frequencies give a clearer picture of the effect of changes to the structure. This paper will give a summary of the results obtained.
FREE

Sound reduction of panels and walls using small‐scale models (A)

Keith W. Walker

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S134-S134 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
The ability to make sound reduction and transmission loss measurements on small‐scale wall models is an attractive proposition for R&D work. Using the impulse response technology offered by the Grozier GTS‐800 acoustical measurement system, measurements of insertion loss were made on single free‐standing panels at normal incidence and at 45 deg. In the range 4 to 40 kHz, the results were in good agreement with mass law theory. Additional measurements of a wall between two ⅛‐scale offices also showed characteristics similar to full‐scale walls, but in the range 1 to 40 kHz.
FREE

Comparison between ASTM nnd FAA procedures for determining airborne sound insulation of building facades (A)

Michael B. Barnhardt

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S134-S134 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
Variations in sound level measurement procedures and the test results between American Society for Testing and Materials, “Standard Guide for Field Measurement of Airborne Sound Insulation of Building Facades” (ASTM Designation E 966), and the Federal Aviation Administration (FAA) Noise Reduction Audit used to determine eligibility for federal funds, are compared. An empirical analysis is used to compare the results of these two methods whose differences are primarily the type and location of the exterior noise source. The contribution of low‐frequency sound to the noise reduction will be presented. The structures used in the analysis are homes participating in the Stapleton Noise Insulation Program (SNIP). The purpose of the SNIP program is to improve the sound insulation of homes, churches, and schools in close proximity to Stapleton International Airport. Sound measurements using both methods were conducted for a sample of homes of varying construction types before and after the construction modifications were implemented. An analysis of the sound insulation improvement as reflected by each of the testing procedures is also presented.
FREE

Low‐frequency resonances in glazing configurations (A)

Gregory C. Tocci

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S135-S135 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
Stiffness combinations of insulating and laminated glass often result in resonances that reduce glazing configuration sound transmission loss. Among these are mass‐air‐mass and mass‐damping material‐mass stiffness resonances. Several resonances and their effect on sound transmission class (STC) and outdoor‐indoor transmission class (OITC) will be discussed. [Work partly supported by Monsanto.]
Contributed Papers
FREE

Development of Standard Guide ASTM E966, “Field measurement of facade sound isolation” (A)

Angelo J. Campanella

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S135-S135 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
Standard Guide ASTM E 966‐84 (similar to ISO 140/5) describes in situ field methods of measuring the ability of windows and doors to prevent the penetration of environmental noise into a room. Recent ASTM review for reapproval resulted in more explicit method options and descriptions. Six different ways are now available where noise reduction and sound transmission loss can be measured, each distinguished by the way that the external sound field is created and measured. The user determines which of these techniques is best suited to his or her field situation. In situ sound fields are unidirectional (single loudspeaker or point source) or quasidiffuse (traffic or flying aircraft), whereas that in the two‐room laboratory methods is diffuse. Three options for measuring the incident sound level are: flush, around 2‐m distance (as in ISO 140/V‐3.1 using traffic), and remote free‐field at an equivalent distance (as in ISO 140/V‐4.1 using a loudspeaker). Sound transmission loss values are adjusted for comparison with E 90 or ISO 140/III laboratory results. Point source adjustment is according to the cosine of the angle of incidence. Line source adjustment is by the “average cosine” [P. T. Lewis, J. Sound Vib. 33, Pt. 3, 127–141 (1974)], but x‐, y‐, and z‐site dimensions are converted to elevation angle and included azimuthal angle of the traffic line as seen from the test facade. The six methods are compared with other FHWA and FAA methods in common use.
FREE

Reduction of plumbing noise in lightweight construction (A)

A. C. C. Warnock and M. J. Morin

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S135-S135 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
Noise from plumbing fixtures can be a source of great annoyance in single‐family and multi‐family homes. Noise‐control articles and textbooks usually recommend the use of resilient supports for pipes and other fixtures as a means of controlling noise. A study recently completed at NRC examined the changes in noise level produced by different types of pipe. different methods of mounting pipes. different wall types. and the addition of sound absorbing materials in walls. Noise sources used included an ISO standard plumbing noise source, a toilet, a sink, and five common bathroom faucets. Closed cell foam rubber supports were found to be the most effective of the resilient materials tested, providing reductions in A‐weighted noise levels of around 20 dB. This paper will give a summary of the results obtained. [The study was funded by Canada Mortgage and Housing Corporation.]
FREE

Sound transmission through very porous concrete blocks (A)

A. C. C. Warnock

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S135-S135 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
Sound transmission loss measurements through a wall constructed from very porous concrete blocks gave some interesting results. The unfinished block wall had a sound transmission class (STC) rating of 14. This was increased to only 29 by screwing a layer of drywall to one side of the block wall. The drywall, while it provides a sealed surface, is not well enough bonded to the blocks and can still vibrate fairly freely. Plastering increased the STC to 43. The porosity of the block increased the effective depth of the air space behind the drywall. This lowered the mass‐air‐mass resonance substantially and, with drywall supported on steel studs, plastered block wall systems gave very good STC ratings. Walls constructed using this type of block can give STC ratings about as high as those obtained with heavier normal weight blocks. Measurements were made down to 63 Hz and revealed that in many cases there are resonances occurring below 125 Hz that have a strong influence on transmission loss values at and above 125 Hz. Measurement to these low frequencies give a clearer picture of the effect of changes to the wall structure. The results obtained will be presented and discussed.
FREE

Suggested infrasound criteria for building spaces (A)

Gregory C. Tocci

J. Acoust. Soc. Am. Volume 88, Issue S1, pp. S135-S135 (1990); (1 page)

Online Publication Date: 14 Aug 2005

Full Text: | Download PDF

Show Abstract
Work by Leo L. Beranek [“Application of NCB Noise Criterion Curves,” Noise Control Eng. J. (Sept.–Oct. 1989)] presents and discusses a set of “balanced noise criterion curves.” These are cited as an improvement in the widely used NC curves and extends them down to the 16‐ and 31.5‐Hz octave bands. These curves are steeply sloped in the very low‐frequency range and are intended to be based wholly on audibility. The author draws upon his experience and a paper by H. Dawson [“Practical Aspects of the Low Frequency Noise Problem,” J. Low Freq. Noise Vib. 1 (1) (1982)] to arrive at a modified set of NC curves extending down to 16 Hz that combine audibility and feelability affects. Examples of the application of these suggested criteria curves will be discussed.